Small range
| Series | Catalogue band · kVA |
|---|---|
| A | 16.5–150 |
| CU | 33–300 |
| P | 10–220 |
| DE | 22–250 |
| K | 7–49 |
| V | 94–285 |
AGG-branded diesel generator sets, selected around daily operating needs and project loads. Mosaic MEP’s proposed scope connects equipment selection with installation, commissioning and service.
Complete generator sets retain AGG’s product identity. Engine, alternator, controls and acoustic arrangement are confirmed for the selected model and duty.
Visit AGG PowerThe series bands below reproduce AGG’s published catalogue categories. They are not uniform prime-power ratings; frequency, model and duty determine the actual output.
| Series | Catalogue band · kVA |
|---|---|
| A | 16.5–150 |
| CU | 33–300 |
| P | 10–220 |
| DE | 22–250 |
| K | 7–49 |
| V | 94–285 |
| Series | Catalogue band · kVA |
|---|---|
| A | 165–1000 |
| CU | 275–850 |
| P | 250–1100 |
| S | 275–880 |
| DE | 250–825 |
| H | 165–935 |
| V | 350–800 |
| Series | Catalogue band · kVA |
|---|---|
| CU | 825–3438 |
| P | 825–1880 |
| M | 1100–4000 |
| MS | 715–2500 |
Catalogue reference: AGG Power, September 2026. Current model data and availability are confirmed in the quotation. Manufacturer catalogue
A focused comparison of 50 Hz, three-phase CU models. Prime power (PRP) is the selection starting point for regular operation with varying loads; standby power (ESP) is shown separately.
| AGG model | Prime · kVA / kW | Standby · kVA / kW | Cummins engine |
|---|---|---|---|
| CU66D5 | 60 / 48 | 66 / 53 | 4BTA3.9G2 |
| CU110D5 | 100 / 80 | 110 / 88 | 6BT5.9G2 |
| CU165D5 | 150 / 120 | 165 / 132 | 6BTAA5.9G12 |
| CU275D5 | 250 / 200 | 275 / 220 | 6LTAA8.9G2 |
Published manufacturer ratings; site temperature, altitude, load profile and starting loads must be checked before selection. The proposed alternator and controller are confirmed in the technical offer.
CU series dataDaily operating hours, average load, motor starting, cooling conditions and service intervals belong in the original selection. Sustained constant-load applications require a separate continuous-duty assessment. Manufacturer operating limits apply to every rating.
Review duty, loads and site conditions; define the equipment, technical documentation and factory testing required for the project.
Coordinate foundations, ventilation, exhaust, fuel arrangements and electrical interfaces within the agreed scope.
Confirm operating checks, protection functions, agreed load testing and operator documentation.
Define service intervals, consumables, critical spares and warranty responsibilities for the selected package.